{"product_id":"ring-type-current-transformer-14mm-id-mce-cp45-14","title":"Ring Type Current Transformer 14mm ID – 30\/5A, 40\/5A | MCE CP45\/14","description":"\u003cp\u003eThe MCE CP45\/14 is a ring type (window) current transformer with a 14mm inner diameter and a 5A secondary output. It is used to step a measured load current down to 5A for ammeters, kWh meters and monitoring equipment, and is suitable for electricians, panel builders and maintenance teams. It is available in 30\/5A and 40\/5A ratios.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Current measurement for ammeters, energy meters and monitoring instruments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInner diameter:\u003c\/strong\u003e 14mm window for the primary conductor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatios:\u003c\/strong\u003e 30\/5A and 40\/5A, 5A secondary\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e Class 1.0, 2.5VA burden\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"color:#2C3892;\"\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRing type design: the primary cable or busbar passes through the centre window\u003c\/li\u003e\n\u003cli\u003eStandard 5A secondary suits most panel ammeters and meters\u003c\/li\u003e\n\u003cli\u003eClass 1.0 accuracy for general metering\u003c\/li\u003e\n\u003cli\u003eCompact body for use in tight panels\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"color:#2C3892;\"\u003eTypical Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCT-operated ammeters on small distribution boards\u003c\/li\u003e\n\u003cli\u003eEnergy metering in sub-distribution panels\u003c\/li\u003e\n\u003cli\u003eLoad monitoring on small cables\u003c\/li\u003e\n\u003cli\u003eSwitchboard and panel building\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"color:#2C3892;\"\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP45\/14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRing type current transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInner diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30A or 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurden\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation \/ frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot specified by supplier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3 style=\"color:#2C3892;\"\u003eWhat’s Included\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e1 x MCE CP45\/14 ring type current transformer (selected ratio)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePlease note:\u003c\/strong\u003e Installation fittings, electrical protection, cables, brackets, meters or accessories are not included unless specifically listed above.\u003c\/p\u003e\u003ch3 style=\"color:#2C3892;\"\u003eInstallation \u0026amp; Compatibility Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSelect the ratio based on the maximum load current of the circuit.\u003c\/li\u003e\n\u003cli\u003eConfirm the primary conductor fits through the 14mm window before ordering.\u003c\/li\u003e\n\u003cli\u003eDo not leave the secondary open-circuit while the primary is energised; short the secondary or connect the meter.\u003c\/li\u003e\n\u003cli\u003eCheck that the connected meter is rated for a 5A CT secondary and that the burden suits the CT.\u003c\/li\u003e\n\u003cli\u003eInstallation should be carried out by a suitably qualified person.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"color:#2C3892;\"\u003eWarranty \u0026amp; Support\u003c\/h3\u003e\u003cp\u003eThis product is supplied with the applicable manufacturer or supplier warranty, subject to correct installation, correct application, and warranty terms. Zisabo supplies quality plumbing, pump, filtration and electrical products with practical support to help customers choose the correct item for their application.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNeed help choosing?\u003c\/strong\u003e If you are unsure whether this product is suitable, contact Zisabo with your cable or busbar size, load current and the meter you intend to connect, and we will assist where possible.\u003c\/p\u003e","brand":"MCE Electrical","offers":[{"title":"30\/5A","offer_id":50649050841345,"sku":"CP45\/14-30\/5","price":200.1,"currency_code":"ZAR","in_stock":true},{"title":"40\/5A","offer_id":50649050874113,"sku":"CP45\/14-40\/5","price":200.1,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/6924\/2369\/files\/Image_9f5c82ea-616b-4b05-a5e6-bd709b927182.png?v=1791614895","url":"https:\/\/www.zisabo.co.za\/products\/ring-type-current-transformer-14mm-id-mce-cp45-14","provider":"Zisabo","version":"1.0","type":"link"}