{"product_id":"surface-mount-appliance-inlet-ip44-ip67-16a-to-63a-3p-4p-5p-mce","title":"Surface Mount Appliance Inlet – IP44 \u0026 IP67 | 16A to 63A | 3P, 4P \u0026 5P | MCE","description":"\u003cp\u003eThe MCE Surface Mount Appliance Inlet range is a set of IEC 60309 \/ CEE industrial inlets that mount on the outside of a machine, generator housing or enclosure to give it a standard plug-in power connection. They suit electricians, panel builders, equipment manufacturers and maintenance teams who need a robust, standard inlet in 16A, 32A or 63A with a choice of IP44 or IP67 protection.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Surface-mounted power inlet for generators, machinery and equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCurrent ratings:\u003c\/strong\u003e 16A and 32A (IP44 and IP67), 63A (IP67 only)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfigurations:\u003c\/strong\u003e 3P (2P+E) 230V, 4P (3P+E) 380V and 5P (3P+N+E) 380V\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e IP44 splash-proof or IP67 waterproof, depending on variant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandard:\u003c\/strong\u003e IEC 60309 \/ CEE format, compatible with matching CEE plugs and couplers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#2C3892;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSurface-mount body for fitting directly onto equipment housings, enclosure walls and frames\u003c\/li\u003e\n  \u003cli\u003eIP44 versions for covered or splash-prone industrial areas, IP67 versions (code ending -X) for exposed and wet outdoor use\u003c\/li\u003e\n  \u003cli\u003eStandard CEE pin and sleeve layout, so it accepts matching IEC 60309 plugs and couplers of the same rating and pin count\u003c\/li\u003e\n  \u003cli\u003eThree current ratings and three pin configurations in one range, so you can match the inlet to the equipment supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#2C3892;\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eGenerator and mobile power plant inlets\u003c\/li\u003e\n  \u003cli\u003eMachinery and equipment power entry points\u003c\/li\u003e\n  \u003cli\u003eWelding and workshop equipment\u003c\/li\u003e\n  \u003cli\u003eTemporary site power and event power distribution\u003c\/li\u003e\n  \u003cli\u003ePump stations, plant rooms and outdoor installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#2C3892;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMCE Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface Mount Appliance Inlet\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60309 \/ CEE\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16A \/ 32A \/ 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfigurations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (2P+E) 230V \/ 4P (3P+E) 380V \/ 5P (3P+N+E) 380V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP44 (16A, 32A) \/ IP67 (16A, 32A, 63A)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface mount\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#2C3892;\"\u003eVariant Reference\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePins\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e513\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003eIP44\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e514\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003ctd\u003e380V\u003c\/td\u003e\n\u003ctd\u003eIP44\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e515\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003e5P\u003c\/td\u003e\n\u003ctd\u003e380V\u003c\/td\u003e\n\u003ctd\u003eIP44\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e513-X\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e514-X\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003ctd\u003e380V\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e515-X\u003c\/td\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003ctd\u003e5P\u003c\/td\u003e\n\u003ctd\u003e380V\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e523\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003eIP44\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e524\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003ctd\u003e380V\u003c\/td\u003e\n\u003ctd\u003eIP44\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e525\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003e5P\u003c\/td\u003e\n\u003ctd\u003e380V\u003c\/td\u003e\n\u003ctd\u003eIP44\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e523-X\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e524-X\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003ctd\u003e380V\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e525-X\u003c\/td\u003e\n\u003ctd\u003e32A\u003c\/td\u003e\n\u003ctd\u003e5P\u003c\/td\u003e\n\u003ctd\u003e380V\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e533-X\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e534-X\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003ctd\u003e380V\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003e535-X\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003ctd\u003e5P\u003c\/td\u003e\n\u003ctd\u003e380V\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#2C3892;\"\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e1 x Surface Mount Appliance Inlet in the selected rating, pin configuration and IP rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note:\u003c\/strong\u003e Plugs, couplers, cables, glands and mounting enclosures are not included.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#2C3892;\"\u003eInstallation \u0026amp; Compatibility Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eConfirm your supply voltage and phase configuration first: 3P for single-phase 230V, 4P for three-phase without neutral, 5P for three-phase with neutral.\u003c\/li\u003e\n  \u003cli\u003eMatch the inlet current rating and pin count to the plug or coupler you will connect to it.\u003c\/li\u003e\n  \u003cli\u003eChoose IP44 for covered or splash-prone areas and IP67 (-X codes) for exposed outdoor or wet environments. 63A is IP67 only.\u003c\/li\u003e\n  \u003cli\u003eFit suitable cable glands and seal entries correctly to maintain the IP rating.\u003c\/li\u003e\n  \u003cli\u003eInstallation must be carried out by a suitably qualified electrician in accordance with SANS 10142.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#2C3892;\"\u003eWarranty \u0026amp; Support\u003c\/h3\u003e\n\u003cp\u003eThis product is supplied with the applicable manufacturer or supplier warranty, subject to correct installation, correct application, and warranty terms. Zisabo supplies quality electrical products with practical support to help customers choose the correct item for their application. If you are unsure which variant is correct for your installation, contact us before ordering.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eNeed help choosing?\u003c\/strong\u003e Send Zisabo your supply voltage, current rating, number of pins and the environment the inlet will be used in, and we will assist where possible.\u003c\/p\u003e","brand":"MCE Electrical","offers":[{"title":"16A – 3P 230V IP44","offer_id":50658392244481,"sku":"513","price":110.4,"currency_code":"ZAR","in_stock":true},{"title":"16A – 4P 380V IP44","offer_id":50658392277249,"sku":"514","price":117.3,"currency_code":"ZAR","in_stock":true},{"title":"16A – 5P 380V IP44","offer_id":50658392310017,"sku":"515","price":135.7,"currency_code":"ZAR","in_stock":true},{"title":"16A – 3P 230V IP67","offer_id":50658392342785,"sku":"513-X","price":308.2,"currency_code":"ZAR","in_stock":true},{"title":"16A – 4P 380V IP67","offer_id":50658392375553,"sku":"514-X","price":326.6,"currency_code":"ZAR","in_stock":true},{"title":"16A – 5P 380V IP67","offer_id":50658392408321,"sku":"515-X","price":431.2,"currency_code":"ZAR","in_stock":true},{"title":"32A – 3P 230V IP44","offer_id":50658392441089,"sku":"523","price":147.2,"currency_code":"ZAR","in_stock":true},{"title":"32A – 4P 380V IP44","offer_id":50658392473857,"sku":"524","price":135.7,"currency_code":"ZAR","in_stock":true},{"title":"32A – 5P 380V IP44","offer_id":50658392506625,"sku":"525","price":159.8,"currency_code":"ZAR","in_stock":true},{"title":"32A – 3P 230V IP67","offer_id":50658392539393,"sku":"523-X","price":419.7,"currency_code":"ZAR","in_stock":true},{"title":"32A – 4P 380V IP67","offer_id":50658392572161,"sku":"524-X","price":443.9,"currency_code":"ZAR","in_stock":true},{"title":"32A – 5P 380V IP67","offer_id":50658392604929,"sku":"525-X","price":488.7,"currency_code":"ZAR","in_stock":true},{"title":"63A – 3P 230V IP67","offer_id":50658392637697,"sku":"533-X","price":924.6,"currency_code":"ZAR","in_stock":true},{"title":"63A – 4P 380V IP67","offer_id":50658392670465,"sku":"534-X","price":1003.9,"currency_code":"ZAR","in_stock":true},{"title":"63A – 5P 380V IP67","offer_id":50658392703233,"sku":"535-X","price":1107.4,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0723\/6924\/2369\/files\/Image_0b324f8e-3dcb-4a12-b7a4-cb179a9d5212.png?v=1791689601","url":"https:\/\/www.zisabo.co.za\/products\/surface-mount-appliance-inlet-ip44-ip67-16a-to-63a-3p-4p-5p-mce","provider":"Zisabo","version":"1.0","type":"link"}